Superheat formula - The formula to calculate superheat uses the current temperature and boiling point. Superheat = Current Temperature – Boiling Point. In this example, the superheat is 10-degrees. Superheat is critical in HVAC because it ensures the liquid refrigerant is boiled off before it leaves the evaporator and heads to the compressor. Even small amounts ...

 
marc5180. 07-07-2010, 09:32 PM. Hi SyWalker, to measure discharge superheat, 1)take the discharge pressure and convert to temp using comparator then. 2) take the discharge temperature. subtract 1 from 2 and that will gve you your discharge superheat. TRASH101. 07-07-2010, 09:49 PM. The discharge superheat is usually the total super heat of the .... Biolife promo codes 2024

How to measure SUPERHEAT and SUBCOOLING! HVAC/R Training Video.How to calculate SUPERHEAT and SUBCOOLING on your air conditioner or refrigerator? R22 R410a … Ferguson HVAC is a national distributor of residential and commercial heating and cooling equipment, parts and supplies. HVAC contractors across the country rely on us for the best unitary and ductless equipment brands and for a wide-range of HVAC products including accessories, controls, air distribution supplies, and service and repair parts. The maximum recommended temperature is often around 150 to 160 degrees Fahrenheit (65.6 to 71.1°C) for the condenser coil. What is normal subcooling for 410A? Normal subcooling for R-410A systems can range from 10 to 20 degrees Fahrenheit (5.6 to 11.1°C) depending on the specific system design and conditions.Quick Tip #9: Superheating and Subcooling. Fully understanding superheat and subcooling is the key to a refrigeration system performing at its optimum level. Closed captioning is available for this video. To activate this feature, play the video and then select “English” from the menu (CC icon) in the upper left corner of the video player.Easy 10 Step-By-Step Guide. Measuring superheat is not all that difficult. All you need are a manifold gauge, a clamp-on thermometer, and a bit of math. We will show you exactly how to measure the superheat for any air conditioner (central air conditioner, split system ACs unit, etc.).3. Calculate superheat: Subtract the saturation temperature from the suction line temperature (Suction Line Temperature – Saturation Temperature = Superheat). Example: If you have a suction line temperature of 65°F (18.3°C) and saturation temperature at 45°F (7.2°C), the superheat calculation will be as follows: 65°F – 45°F = 20°F ...Jess Gordon is the service manager at Tempo Mechanical Services, Irving, TX. The company was Contracting Business magazine’s 2003 Residential Contractor of the Year. Jess can be reached at 972-579-2000, or by e-mail at [email protected]. Superheat is a way to ensure that the system is boiling off all of the liquid before it exits the evaporator.We measure the actual superheat with the low side red gauge and clamp-on thermometer (on suction line). Quick Example: Let’s say that you have used the manifold gauge (red part) and clamp-on thermometer to measure actual superheat using this 10 step procedure.You got an actual measured superheat of 5°F.Now, you consult the target superheat chart …Steam at 213 degrees F is superheated by 1 degree F. Superheat is then any temperature of a gas above the boiling point for that liquid. When a refrigerant liquid boils at a low temperature of 40 degrees in a cooling coil and then the refrigerant gas increases in temperature, superheat has been added. If this refrigerant changed from a …Superheat is a crucial factor in HVAC systems that helps ensure optimal performance and efficiency. In simple terms, superheat refers to the temperature difference between the refrigerant vapor and its saturation temperature at a particular pressure. It plays a significant role in the refrigeration cycle by indicating the amount of heat ...The formula to calculate both superheat and subcooling is more than easy as all you need to do is just subtract the current temperature from the boiling or condensation temperature of the water gas. If you are calculating superheat, you will need to subtract the current temperature from the boiling temperature which will be as:Superheat and subcooling are the two fundamental concepts in any HVAC system. Basically, superheat is the temperature a refrigerant vapor needs to maintain its gaseous state as it passes through the evaporator coil. While subcooling is the additional cooling that takes place in a condenser after the refrigerant has already been condensed.Learn how to check evaporator superheat in HVAC and refrigeration systems with this informative video. You will see how to use testo smart probes and understand the importance of superheat for ...Superheat = Current Temperature – Boiling Point. Superheat is measured by its temperature above its boiling point. If a refrigerant vapor boiling point is 140 degrees, for example, then anything about that pressure would be too high for that specific refrigerant. To calculate the measurement of subcooling, the formula is: Subcooling = Boiling ...The excess energy = 2 741.7 - 2 706.7 = 35 kJ/kg, and this is used to raise the temperature of the steam from the saturation temperature of 120 °C to 136 °C. The degree of superheat can be determined either by using superheated steam tables, or by using a Mollier chart.The formula for calculating eccentricity is e = c/a. In this formula, “e” refers to the eccentricity, “a” refers to the distance between the vertex and the center and “c” refers to... Step 3. Subtract the evaporator saturation temperature from the thermocouple temperature. This difference is the system superheat. This shows the temperature rise above the bubble point temperature of the system. Review the operating specifications for your system to determine the proper superheat. Inadequate superheat can cause liquid ... Superheat should be checked after the compressor has run continually for at least ten minutes to allow the system refrigerant and oil to settle. The indoor unit's return air temperature and airflow should be as close to normal operating conditions as possible as well as the outdoor ambient. Setting Superheat.To determine the Target Superheat for an air conditioning system with a fixed orifice (such as a piston or capillary tube) measure the indoor WB (wet bulb) temperature with a digital psychrometer and the outdoor DB (dry bulb) temperature with a standard digital temperature reader. Input these temperatures in a superheat chart, calculation, app, or digital manifold set in order to determine the ...WB is 64° F, DB is 96° F. Target Superheat Formula = [ (3 x WB) – 80 – DB] /2. [ (3 x 64) – 80 – 96] /2 = Target Superheat. 3 x 64=192, 192-80=112, 112-96=16 16/2=8° F of Target …Formula to calculate super heat. The temperatures must be measured at the same point and simultaneously. Example: Suppose the evaporator outlet temperature is 100 degrees and its inlet is 90 degrees, calculate … The clamp-on thermometer reads 77°F. Here is how we use the subcooling formula to manually calculate the subcooling in this system: Subcooling (R-22) = 89°F – 77°F = 12°F. We see that the calculated subcooling for R-22 refrigerant in this system is 12°F. This is the manual calculation. For more tips, visit our website, http://www.edgetekhvac.com.To download a copy of our job sheet, visit our online literature library at: http://literature.n...Discharge superheat formula. It is obtained from the difference in the temperature. Discharge Superheat = Discharge line temperature at compressor – Temperature of saturated liquid. It is measured at the service valve provided at the outlet of the compressor. This service valve is six inches far from the compressor outlet.The excess energy = 2 741.7 - 2 706.7 = 35 kJ/kg, and this is used to raise the temperature of the steam from the saturation temperature of 120 °C to 136 °C. The degree of superheat can be determined either by using superheated steam tables, or by using a Mollier chart.Easy 10 Step-By-Step Guide. Measuring superheat is not all that difficult. All you need are a manifold gauge, a clamp-on thermometer, and a bit of math. We will show you exactly how to measure the superheat for any air conditioner (central air conditioner, split system ACs unit, etc.).Good Subcooling Value for R-410A: Similar to superheat, the ideal subcooling value for R-410A can vary depending on factors like system design and operating conditions. However, a common target for R-410A systems is to achieve a subcooling value in the range of 8 to 15 degrees Fahrenheit (°F) or approximately 4.4 to 8.3 degrees Celsius (°C).As a new parent, you have many important decisions to make. One is to choose whether to breastfeed your baby or bottle feed using infant formula. As a new parent, you have many imp...Superheat is a measured value. It is the difference between two temperatures. Superheat is measured as the difference between the actual temperature of the refrigerant vapor and the saturation temperature of the refrigerant at that same point. Superheat on the system's low side can be divided into two types: evaporator superheat and total (or ...High superheat is an AC problem that won’t go away by itself (except due to the #4 cause). We have to fix high superheat. In order to do that, it’s particularly useful to understand what causes high superheat in air conditioners. There are 6 common high superheat culprits that we always check, and we’ll go over all of them one-by-one.. Namely, a high …Learn about superheat — what it is and how it occurs in a refrigeration system with Don Gillis, lead technical trainer at Emerson. For more content on heatin...A stock's yield is calculated by dividing the per-share dividend by the purchase price, not the market price. A stock&aposs yield is calculated by dividing the per-share dividend b...Superheat is checked by measuring the temperature of the vapor line, measuring the pressure, then subtracting the saturated temperature from the measured temperature. In the case of a blend, you Simply read the saturated temperature next to the pressure in the vapor (dew point) column of the chart.Subtract the two numbers to get superheat. For example, 68 psi suction pressure on a R-22 system converts to 40 ° F. Let's say the suction line temperature is 50 ° F. Subtracting the two numbers gives us 10 ° F of superheat. Superheat for most systems should be approximately 10F measured at the evaporator; 20 ° F to 25 ° F near the compressor.The formula to calculate superheat uses the current temperature and boiling point. Superheat = Current Temperature – Boiling Point. In this example, the superheat is 10-degrees. Superheat is critical in HVAC because it ensures the liquid refrigerant is boiled off before it leaves the evaporator and heads to the compressor. Even small amounts ...1 Jul 2020 ... Welcome to Enertech University, online training by Enertech. In this session learn how to do superheat and subcooling calculations presented ...Apr 22, 2024 · Determine the amount of subcooling by subtracting the liquid line temperature from the saturation temperature of the refrigerant. According to industry standards, superheat should be 12-15 degrees in ambient air temperature below 85°F and 8-12 degrees in warmer air. Subcooling should be 5-18 degrees, with higher values when the equipment has a ... Bryan shows the best ways to find target superheat on fixed orifice HVAC systems, including using charts, apps, and other resources. You can find your target...Superheat Formula. This is the superheat formula by definition: Superheat = T vapor after evaporator coil exit – T saturated refrigerant. In practice, we have to measure both of these temperatures.Calculate. This free online tool allows HVAC professionals to quickly calculate Superheat and Subcooling measurements for both R22 & R410A refrigerants.Mar 1, 2020 · How to measure SUPERHEAT and SUBCOOLING! HVAC/R Training Video.How to calculate SUPERHEAT and SUBCOOLING on your air conditioner or refrigerator? R22 R410a R... For this example the Liquid line Temp is 95 degrees. Subtract the Liquid line Temperature from the Liquid Saturation Temperature and you get a Subcooling of 15. “Typically” on TXV systems the Superheat will range between 8 to 28 degrees with a target of about 10 to 15 degrees. The Subcool range on TXV systems will range from about 8 to 20. Steam at 213 degrees F is superheated by 1 degree F. Superheat is then any temperature of a gas above the boiling point for that liquid. When a refrigerant liquid boils at a low temperature of 40 degrees in a cooling coil and then the refrigerant gas increases in temperature, superheat has been added. If this refrigerant changed from a …The SI equivalent of this formula would be: TSH=IWB- (OAT-IWB)/2-4.44. In my understanding, this formula provides an approximation for the expected line temperature and 4.44C (40F) represents Tevap. The indoor wet bulb (IWB) and outdoor dry bulb (OAT) temperatures represents the boundary conditions in terms of temperature in …How is superheated steam calculated? The excess energy = 2 741.7 - 2 706.7 = 35 kJ/kg, and this is used to raise the temperature of the steam from the saturation temperature of 120 °C to 136 °C. The degree of superheat can be determined either by using superheated steamtables, or by using a Mollier chart.LEARN METRICS HVAC SYSTEMS Based On Specifications Outdoor 107% 110.6 122.F X x x x x X X x x X X X x x X X X x x X X x x X x x x X X 2.5'? '.5aFThat means understanding and measuring all three types of superheat: evaporator, total, and duct system. 1. Evaporator superheat. To measure evaporator (indoor coil) superheat, first measure the suction line temperature at the evaporator outlet. Next, measure the refrigerant pressure at the suction line of the indoor coil. 3. Calculate superheat: Subtract the saturation temperature from the suction line temperature (Suction Line Temperature – Saturation Temperature = Superheat). Example: If you have a suction line temperature of 65°F (18.3°C) and saturation temperature at 45°F (7.2°C), the superheat calculation will be as follows: 65°F – 45°F = 20°F ... As a spreadsheet, Microsoft Excel has multiple uses. You can use it to track inventory, record customer data or you can even use it to record your business's financial information....AC SERVICE TECH, LLC. Thanks for all your continued support! I appreciate all the comments, questions, and responses that I receive from each of you. I look forward to responding to many more! If you have an HVACR related question, drop it in the comment section of one of the YouTube videos at the AC Service Tech YouTube Channel and I will do ...Basic steam desuperheating. Desuperheating is the process by which superheated steam is restored to its saturated state, or the superheat temperature is reduced.Most desuperheaters used to restore the saturated state produce discharge temperatures approaching saturation (typically to within 3°C of the saturation temperature as a …Once the refrigerant has boiled to a vapor then any temperature above and beyond the boiling point is known as the Superheat. In other words, Superheat is any temperature of a gas that is above the boiling point for that liquid. The reason that Superheat is so important to measure is that it can give you a direct indicator as to what is wrong ...With a high superheat of ~ 40 °C, the central equiaxed parts of the slabs consisted of randomly oriented fine dendrites but with a low superheat of ~ 10 °C, coarse globular structures formed.Here is a chart that contains low superheat causes and low subcooling causes: Indoor airflow (CFMs) is too low. Oversized AC unit. Outdoor airflow is too low (or condenser coils heat exchange is impeded). High refrigerant charge (overcharged AC unit). Metering device (TXV, AEV, or piston) is overfeeding.The formula to calculate both superheat and subcooling is more than easy as all you need to do is just subtract the current temperature from the boiling or condensation temperature of the water gas. If you are calculating superheat, you will need to subtract the current temperature from the boiling temperature which will be as:Superheat and Reheat. As for the Carnot cycle, the thermal efficiency tends to increase as the average temperature at which energy is added by heat transfer increases. This is the common feature of all thermodynamic cycles. One of possible ways is to superheat or reheat the working steam. Both processes are very similar in its manner:You can find the distance between two points by using the distance formula, an application of the Pythagorean theorem. Advertisement You're sitting in math class trying to survive ...Knowing the present value of an annuity is important for retirement planning. This guide walks you through how it works and how to calculate it. Calculators Helpful Guides Compare ...As we will see in the R-22 and R-410A examples at the end, target superheat for a system using R-22 and the target superheat for a system using R-410A (or any other refrigerant) are the same. Only the DB and WB temperatures determine the target superheat. Here is the formula we use to calculate superheat: Target Superheat = (3 × TWet Bulb ...Too much refrigerant in the evaporator coil. This is the case in the #4 and #5 causes in the list below. Not enough indoor heat to adequately vaporize the refrigerant. Causes #1 and #2 cover this well, and we also have to check the outdoor coils (cause #3). There are 6 common instances that cause low superheat.The clamp-on thermometer reads 77°F. Here is how we use the subcooling formula to manually calculate the subcooling in this system: Subcooling (R-22) = 89°F – 77°F = 12°F. We see that the calculated subcooling for R-22 refrigerant in this system is 12°F. This is the manual calculation.Answer #1: Discharge Superheat = Temperature of discharge line 6” downstream of the compressor discharge service valve (semi-hermetic) or discharge connection (hermetic) – saturated temperature of the liquid line (obtained from P/T conversion of liquid line pressure). Answer#2: Gage pressure is the pressure your …This video I instruct you on how to calculate and go over the super heat fomula. This video also gives you some basic information on what super heat is. Reme... The formula to calculate both superheat and subcooling is more than easy as all you need to do is just subtract the current temperature from the boiling or condensation temperature of the water gas. If you are calculating superheat, you will need to subtract the current temperature from the boiling temperature which will be as: Dec 27, 2023 · The SI equivalent of this formula would be: TSH=IWB- (OAT-IWB)/2-4.44. In my understanding, this formula provides an approximation for the expected line temperature and 4.44C (40F) represents Tevap. The indoor wet bulb (IWB) and outdoor dry bulb (OAT) temperatures represents the boundary conditions in terms of temperature in which the equipment ... QUICK FACTS. According to Orr, superheat tells a technician how far liquid is being fed through the evaporator. Higher superheat means the liquid is making it through less of the coil before becoming fully vapor, and lower superheat means it is making it farther through the coil.What Is Superheat? First of all, we all know that most elements can exist as a liquid, gas or solid. Of these three states, only a gas (also sometimes called vapor or steam) can be superheated. 1.To calculate superheat, we must have the steam pressure (P, bars) and temperature (T, ºC). Superheat is the difference between steam temperature, T, and saturation temperature, Tsat, at pressure, P. (To use English units, you will have to convert to metric to run the routine, then convert back to English when you get the answer). The method is ... How to check, measure, and read superheat and subcooling on a central air conditioner unit. In this video I do not go into the details of superheat and subco... Here is a chart that contains low superheat causes and low subcooling causes: Indoor airflow (CFMs) is too low. Oversized AC unit. Outdoor airflow is too low (or condenser coils heat exchange is impeded). High refrigerant charge (overcharged AC unit). Metering device (TXV, AEV, or piston) is overfeeding.Example 2: Target Superheat Calculation (This calculation will get you close to manufacturer superheat chart results) WB is 64° F, DB is 96° F. Target Superheat Formula = [ (3 x WB) – 80 – DB] /2. [ (3 x 64) – 80 – 96] /2 = Target Superheat. 3 x 64=192, 192-80=112, 112-96=16 16/2=8° F of Target Superheat. 8° F of Target Superheat. Total Superheat. Calculating Evaporator Superheat. Step 1: Measure Suction Line Pressure. Step 2: Determine Saturation Temperature. Step 3: Measure Suction Line Temperature. Step 4: Calculate Evaporator Superheat. Calculating Compressor Superheat. Step 1: Measure Discharge Line Pressure. Answer #1: Discharge Superheat = Temperature of discharge line 6” downstream of the compressor discharge service valve (semi-hermetic) or discharge connection (hermetic) – saturated temperature of the liquid line (obtained from P/T conversion of liquid line pressure). Answer#2: Gage pressure is the pressure your …This can be seen by measuring the superheat. To measure evaporator superheat: Record the actual temperature at the TXV bulb with a probe. Record the evaporating pressure at the TXV bulb. (Low side gauge pressure) Convert the evaporating pressure to temperature by using a pressure/temperature comparator. Subtract the temperature converted on the ...Here is the formula for calculating superheat and total superheat: Superheat = T vapor after evaporator coil exit – T saturated refrigerant when it turns to 100% vapor. Total Superheat = T vapor at service valve; prior to entering the compressor – T saturated refrigerant when it turns to 100% vaporMar 16, 2022 · Learn how to check evaporator superheat in HVAC and refrigeration systems with this informative video. You will see how to use testo smart probes and understand the importance of superheat for ... Step 3. Subtract the evaporator saturation temperature from the thermocouple temperature. This difference is the system superheat. This shows the temperature rise above the bubble point temperature of the system. Review the operating specifications for your system to determine the proper superheat. Inadequate superheat can cause liquid ...September 14, 2001. The dire ramifications of under- and overcharging an air conditioner or heat pump were covered last month ("Using the Superheat Method to Charge A/C Systems,"The News, Aug. 13, page 1). The first installment also contained a basic explanation of what superheat is and what it tells you about the condition of the …How to measure SUPERHEAT and SUBCOOLING! HVAC/R Training Video.How to calculate SUPERHEAT and SUBCOOLING on your air conditioner or refrigerator? R22 R410a R...16 Table 3. Compressed Water and Superheated Steam 0.01 MPa (ts = 45.806 °C) 0.02 MPa (t s = 60.058 °C) 0.03 MPa (t s = 69.095 °C) v ρh s t, °Cv h s v ρ h s 1.010 27 989.83 191.81 0.649 20 t s(L) 1.017 16 983.13 251.42 0.832 02 t s(L) 1.022 24 978.25 289.27 0.944 07 14 670. 0.068 166 2583.9 8.1488 t s(V) 7648.0 0.130 75 2608.9 7.9072 tCalculate Superheat using the formula: Superheat = Evaporator Temperature – Saturation Temperature. GEGCalculators. GEG Calculators is a comprehensive online platform that offers a wide range of calculators to cater to various needs. With over 300 calculators covering finance, health, science, mathematics, and …3 Aug 2019 ... In this HVAC Service Training Video, I explain Step By Step How to Check the Refrigerant Charge using the Total Superheat Method for Systems ...Step 3. Subtract the evaporator saturation temperature from the thermocouple temperature. This difference is the system superheat. This shows the temperature rise above the bubble point temperature of the system. Review the operating specifications for your system to determine the proper superheat. Inadequate superheat can cause liquid ...Learn the definition, formula and examples of superheat and subcooling, two important terms in the refrigeration cycle. Superheat is when you heat vapor above its boiling point, while subcooling is when you cool a …Hi The carrier bus AC manual states "it uses a nonadjustable block valve with an 8° F superheat ... SUPERHEAT: 8° F is wrong ? ... equation. To ...Convert pressure to temperature using an app, slide, or chart. Measure the suction line temperature where it leaves the condensing unit, staying 4-6 inches from the compressor. Determine the amount of …

Saturation Temperature. (oC) Enthalpy of Superheated Steam (kJ/kg) Temperature (oC) Saturation. 200. 250. 300. 350.. Craigslist hampton new hampshire

superheat formula

File:Example 1 - Ideal Rankine Cycle with Superheat.EES 3/31/2023 11:06:38 AM Page 3 EES Ver. 10.836: #2191: For use only by students and faculty in Mechanical Engineering, Univ. of Idaho, Moscow, Idaho "The back work ratio (bwr) is defined as," bwr = W_dot_p/W_dot_t "Mass flow rate of the cooling water"A Superheat Subcooling Calculator can help us achieve these precise calculations quickly and conveniently. Definition. Superheat Subcooling refers to two separate but interconnected processes in an HVAC system. Superheat is the surplus heat added to a refrigerant, beyond its boiling point. Subcooling refers to the cooling of the …The superheat setting is an essential parameter to ensure the TEV operates effectively. thermostatic expansion valve (TEV) Superheat refers to the additional temperature increase of a gas after it has fully transitioned from a liquid to a gas phase. In the context of a TEV, superheat is the temperature difference between the refrigerant …As a spreadsheet, Microsoft Excel has multiple uses. You can use it to track inventory, record customer data or you can even use it to record your business's financial information....The clamp-on thermometer reads 77°F. Here is how we use the subcooling formula to manually calculate the subcooling in this system: Subcooling (R-22) = 89°F – 77°F = 12°F. We see that the calculated subcooling for R-22 refrigerant in this system is 12°F. This is the manual calculation.As a spreadsheet, Microsoft Excel has multiple uses. You can use it to track inventory, record customer data or you can even use it to record your business's financial information....Example 2: Target Superheat Calculation (This calculation will get you close to manufacturer superheat chart results) WB is 64° F, DB is 96° F. Target Superheat Formula = [(3 x WB) – 80 – DB] /2 [(3 x 64) – 80 – 96] /2 = Target Superheat. 3 x 64=192, 192-80=112, 112-96=16 16/2=8° F of Target Superheat. 8° F of Target SuperheatAnswer #1: Discharge Superheat = Temperature of discharge line 6” downstream of the compressor discharge service valve (semi-hermetic) or discharge connection (hermetic) – saturated temperature of the liquid line (obtained from P/T conversion of liquid line pressure). Answer#2: Gage pressure is the pressure your …Bobbie is carving out its own piece of an infant formula market poised to be a valued at $103 billion by 2026. Organic infant formula company Bobbie is taking a hint from its stagg...Learn the formula and the steps to measure superheat, the amount of heat required to change the state of a substance from a liquid to a vapor. Find out how to use superheat for HVAC applications, optimize …Formula to calculate super heat. The temperatures must be measured at the same point and simultaneously. Example: Suppose the evaporator outlet temperature is 100 degrees and its inlet is 90 degrees, calculate …Is there a scientific formula for funny? Read about the science and secrets of humor at HowStuffWorks. Advertisement Considering how long people have pondered why humor exists -- a...Here is the formula for calculating superheat and total superheat: Superheat = T vapor after evaporator coil exit – T saturated refrigerant when it turns to 100% vapor. Total Superheat = T vapor at service valve; prior to entering the compressor – T saturated refrigerant when it turns to 100% vaporWe would like to show you a description here but the site won’t allow us.The total superheat method is used to measure the increase in temperature of the vapor refrigerant at the evaporator plus any additional temperature change that occurs while the vapor refrigerant travels to the outdoor unit. Below is a picture of refrigerant superheating from 40 °F to 54°F inside an evaporator coil.Step 10: Compare Superheat to Recommended Values. Refer to the manufacturer's specifications or industry guidelines to determine the recommended superheat range for the specific HVAC system and refrigerant type. Compare the measured superheat value to the recommended range to assess system performance. Step 11: Adjust Superheat (If Necessary)Mar 16, 2022 · Learn how to check evaporator superheat in HVAC and refrigeration systems with this informative video. You will see how to use testo smart probes and understand the importance of superheat for ... Is there a scientific formula for funny? Read about the science and secrets of humor at HowStuffWorks. Advertisement Considering how long people have pondered why humor exists -- a....

Popular Topics